SLS-B+C50/1+1

Surge arrester

Lightning and surge arrester for single phase lines (F+N) 230 V.

Combined type 1 and 2 (Class B + C) protector, suitable for protection of low voltage lines against lightning strikes and surges of up to 25kA (10/350) in TT (TNS) networks.

Recommended for industrial facilities or buildings, with a risk of partial lightning currents, induced overvoltages during a lightning strike or switching overvoltages.

Characteristics
  • Single phase protector (1 pole + NPE).
  • It provides high protection and low residual stress, for its combination of high performance varistors and encapsulated spark gap.
  • Easily replaceable plug-in modules with locking system.
  • Base and modules configured for secure mounting.
  • Easy maintenance through local fault locator.
Download data sheet
PDF icon Surge arrester SLS-B+C50/1+1
Technical specifications
Description Reference NºPhases Grade of proteccion Range Tª
work
A (mm) B (mm) C (mm) D (mm) E (mm) Weight (g)
SLS-B+C50/1+1 370241 F+N IP20  -40º a 80ºC 36 82 72 45 48 240
SLS-B+C50/220V 370247 - IP20  -40º a 80ºC - - - 45 48 95
Parameters   L-N NPE
Rated voltage Un 230 V AC -
Maximum working voltage Uc 260 V AC 255 V AC
Current peak value of lightning (10/350μs) Iimp 12,5 kA 25 kA
Nominal discharge current (8/20μs) In 30 kA 30 kA
Maximum discharge current (8/20μs) Imax 60 kA 60 kA
Protection level Up <1'2 kV <1'5 kV
Backup fuse maximum   160 A gL/gG -
Response time tA 25 ns 100 ns
Wire cross-section, rigid min/max   1-35mm2
Wire cross-section, flexible min/maxIndicador   1-25mm2
Local fault indicator   yes no
Mounting type   rail DIN 35mm
  • lEC 61.643-11:2011
  • UNE 21.186:2011
  • EN 61.643-11 :2012
  • NFC 17-102:2011
  • UNE 61.643-11 :2013
  • UNE EN 60.664-1:2008
  • lEC 62.305-1, 2, 3 y 4
  • RBT

SLS-B+C50/3+1

Lightning and surge arrester for three phase lines (3F+N) 230/400 V.

Combined type 1 and 2 (Class B + C) protector, suitable for protection of low voltage lines against lightning strikes and surges up to 50kA (10/350) in TT (TNS) networks.

Recommended for industrial facilities or buildings, with a risk of partial lightning currents, induced overvoltages during a lightning strike or switching overvoltages.

Characteristics
  • Three phases protector (3-poles + NPE).
  • Provides high protection and low residual stress, for its combination of high performance varistors and encapsulated spark gap.
  • Easily replaceable plug-in modules with locking system.
  • Base and modules configured for secure mounting.
  • Easy maintenance through local fault locator.
Download data sheet
PDF icon SLS-B+C50/3+1
Technical specifications
Description Reference NºPhases Grade of proteccion Range Tª work A (mm) B (mm) C (mm) D (mm) E (mm) Weight (gr/m)
SLS-B+C50/3+1 370242 3F+N IP20 de -40º a 80ºC 72 82 72 45 48 460
SLS-B+C50/220V 370247 - IP20 de -40º a 80ºC - - - 45 48 95
Parameters   L-N NPE
Rated voltage Un 230 V AC -
Maximum working voltage Uc 260 V AC 255 V AC
Current peak value of lightning (10/350μs) Iimp 12,5 kA 50 kA
Nominal discharge current (8/20μs) In 30 kA 50 kA
Maximum discharge current (8/20μs) Imax 60 kA 100 kA
Protection level Up <1,2 kV <1,5 kV
Backup fuse maximum   160 A gU/gG -
Response time tA 25 ns 100 ns
Wire cross-section, rigid min/max   1-35mm2
Wire cross-section, flexible min/maxIndicador   1-25mm2
Local fault indicator   yes no
Mounting type   DIN rail 35mm
  • lEC 61.643-11:2011
  • UNE 21.186:2011
  • EN 61.643-11 :2012
  • NFC 17-102:2011
  • UNE 61.643-11 :2013
  • UNE EN 60.664-1:2008
  • lEC 62.305-1, 2, 3 y 4
  • RBT

Related products

Surge protection SLS-B+C100

SLS-B+C100

Surge protector

Surge protection SLS-B+C20

SLS-C20

Surge protector

INGESCO PDC Lightning rod

INGESCO PDC ESE Lightning rod

Lightning rod with ESE (Early Streamer Emission) system

REQUEST INFORMATION NOW